Journal of Forensic Dental Sciences
IAFO CONFERENCE 2018 GOA - http://iafo2018goa.com/ Users Online: 701 
Home Print this page  Email this page Small font size Default font size Increase font size
Wide layoutNarrow layoutFull screen layout
  Home | About JFDS | Editorial Board | Search | Ahead of print | Current Issue | Archives | Instructions | Subscribe | Online submission | Contact us | Advertise | Login 


 
  Table of Contents  
ORIGINAL ARTICLE
Year : 2013  |  Volume : 5  |  Issue : 1  |  Page : 47-51  

Digital approach for measuring dentin translucency in forensic age estimation


Department of Oral Pathology and Microbiology, Mahatma Gandhi Postgraduate Institute of Dental Sciences, Puducherry, India

Date of Web Publication5-Jul-2013

Correspondence Address:
Simranjit Singh
Department of Oral Pathology and Microbiology, Mahatma Gandhi Postgraduate Institute of Dental Sciences, Indira Nagar, Gorimedu, Puducherry - 605 006
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0975-1475.114558

Rights and Permissions
   Abstract 

Background: Dentin translucency is best suited for age estimation not only in terms of accuracy but also in terms of simplicity. Conventionally, translucency has been measured using calipers. Computer-based methods have been proposed for the same, although these required the use of custom-built software programs. Objectives: The objectives of the study were to use a simple digital method to measure dentinal translucency on sectioned teeth and to compare digital measurements to conventionally obtained translucency measurements. Materials and Methods: Fifty extracted permanent teeth were collected and were sectioned to 250 μm. Translucency measurements were obtained using the digital method and compared with those obtained using a caliper. Results: Correlation coefficients of translucency measurements to age were statistically significant for both methods (P < 0.001), and marginally higher for the conventional approach (r = 0.4671). Application of derived linear regression equations on an independent sample (n = 10) revealed a similar ability of both the methods to assess age to within ±5 years of the actual age. Conclusion: The translucency measurements obtained by the two methods were very similar, with no clear superiority of one method over the other. Hence, further studies on a large scale are warranted to determine which method is more reliable to estimate the age.

Keywords: Age assessment, computer software, dentinal translucency, forensic odontology, Gustafson′s criteria


How to cite this article:
Singh S, Venkatapathy R, Balamurali P D, Charles N, Suganya R. Digital approach for measuring dentin translucency in forensic age estimation. J Forensic Dent Sci 2013;5:47-51

How to cite this URL:
Singh S, Venkatapathy R, Balamurali P D, Charles N, Suganya R. Digital approach for measuring dentin translucency in forensic age estimation. J Forensic Dent Sci [serial online] 2013 [cited 2019 Sep 15];5:47-51. Available from: http://www.jfds.org/text.asp?2013/5/1/47/114558


   Introduction Top


Age estimation is an important sub discipline of forensic sciences. [1],[2] Estimation of a human corpse's age forms a pertinent part of forensics during the identification process of a cadaver that cannot be identified otherwise due to denaturation of the individual characteristics that would lead to an optical recognition. [3] Teeth usually survive postmortem destruction and are considered to be better suited for estimating age. [2],[4] The methods of age estimation using teeth include analyzing tooth development and eruption, studying tooth degradation and measuring biochemical and trace element changes in dental structures. [3],[5]

Different methods have been proposed in the course of time of age estimation via human biological characteristics. [3] Among the various methods proposed, Gustafson's morpho-histologic approach [6] occupies a central position in estimating age using teeth. Studies on Gustafson's variables found that dentin translucency was best suited for age estimation when used alone. [4],[7] Miles suggested that measuring the regressive changes was a better approach for age assessment than visually grading them. Bang and Ramm reported that there is a significant increase in root transparency with age. [3],[8]

Traditionally, translucency has been measured using vernier calipers. [4],[8],[9] Recently, however, attempts to quantify translucency using digital aids have been made. [4],[10],[11] But, these computer-based methods require the use of custom-built software programs and required capturing tooth images on a video camera, converting the analog signal to a digital signal, and subsequent image processing. [4]

The purpose of this article is to use a simple digital method for quantifying dentinal translucency and to compare digital measurements to conventionally obtained translucency measurements.


   Materials and Methods Top


Tooth sampling and sectioning

Fifty extracted permanent teeth from 50 different individuals in the age group of 20-75 years (mean age, 45.34 years) were obtained from the Department of Oral and Maxillofacial Surgery of our institution. Single rooted permanent teeth extracted for valid clinical reasons such as orthodontic treatment, periodontal disease and caries were included in the study. Carious teeth were included in the sample provided the roots of the teeth were unaffected macroscopically. Grossly decayed teeth, impacted teeth, teeth with severe attrition, root caries and internal resorption were excluded from the study. Multirooted teeth were also excluded from the study. Following thorough cleaning, the extracted teeth were sectioned using micro motor, diamond disks and carborundum stones [Figure 1]. The teeth were sectioned longitudinally to 250 μm in the buccolingual plane as close as possible to the central axis of the tooth.
Figure 1: Armamentarium used for tooth sectioning

Click here to view


Caliper-based translucency measurement

Conventional translucency measurements were made by placing the tooth sections in front of a constant light source and measuring the maximum distance between the apical limit and the most coronal extent of translucency within the root using a caliper. The measurements made were sensitive to 0.1 mm.

Digital translucency measurement

The method used in this study for measuring dentin translucency has been adapted from different steps described by Johansen and Bowers [12] for digital analysis of bitemark evidence and by Acharya [4] for digital analysis of dentin translucency. The computer hardware used in the method included a Dell 2.26 GHz CPU with 4 GB RAM and a 15.4 inch LCD monitor and a BenQ scanner 5000 (BenQ Corporation, Taiwan). Each tooth section was placed next to an American Board of Forensic Odontology (ABFO) No. 2 scale (Tritech Forensics, Phoenix, AZ, USA) on the scanner platen.

The long axis of the section was aligned parallel to the y-axis of the scale. Prior to scanning, the scanner setting was verified to be 100% of the original to ensure life-size scanned images. Subsequently, an image of 600 dpi resolution of the section with scale was obtained [Figure 2]. Scanned images were imported to Adobe Photoshop version 7.0 image-editing software for viewing and measuring the extent of translucency. Translucent dentin appears as a dark region on the tooth section as compared with the other dental tissues [Figure 2]. Translucency was measured using a number of tools available on Adobe Photoshop.
Figure 2: Scanned image of a tooth section with an American Board of Forensic Odontology no. 2 scale. Translucent dentin (arrow) appears as a dark area on the section

Click here to view


For measuring translucency, Photoshop's in-built "rulers" were activated along the edges of the image (on the Menu Bar, choose View > Rulers, or Ctrl + R, or Command + R for Macintosh systems). The units were ensured to be in millimeters by comparing with the reference ABFO No. 2 scale. In the event units are not in millimeters, choose Edit > Preferences > Units and Rulers and select "mm" under Units and click OK. Once the rulers were activated, guides were placed corresponding to the apical and coronal extent of root dentin translucency by clicking the cursor within the x-axis (horizontal part) of the ruler and dragging onto the image [Figure 3]. To move a guide to the desired location, the Move Tool was used; alternatively, the Ctrl key was held down (Command key for Macintosh systems).
Figure 3: Measurement of dentin translucency using Adobe photoshop. Guides A and B correspond to apical and coronal limits of translucent dentin, respectively

Click here to view


Once the respective guides had been placed at the apical and coronal extents of root dentin translucency, the distance between them was obtained using the Measure Tool on the Toolbox. Using this tool, a line was drawn between the guides; the distance (D1) was displayed in the Options Bar [Figure 3]. If the Options Bar is not displayed, it can be activated by choosing Window > Options. Measurements obtained using the Measure Tool were sensitive to 0.1 mm. The measuring line drawn was kept vertical by holding down the Shift key.

Statistical analysis

Translucency measurements obtained from both methods were correlated to known age using linear regression analysis. Pearson's correlation coefficients obtained for both methods were noted and the regression equations derived used to calculate age on a control sample of 10 sections (obtained from 10 subjects whose ages ranged between 27 and 70 years). These sections were not used in deriving the regression formulas. The difference between estimated and known age for both methods was compared.


   Results Top


Pearson's correlation coefficients (r) and linear regression equations are shown in [Table 1]. The correlation coefficients were statistically significant for both conventional and digital methods (P < 0.001). The correlation coefficient was slightly higher for conventional measurements (r = 0.4761) as compared with digital measurements (r = 0.4757).
Table 1: Correlation coefficient (r) and regression equations derived from the conventional and digital translucency measurements

Click here to view


Application of linear regression equations on the control sample (n = 10), which included the sections that were not used in deriving the regression formulas, showed that both the methods could estimate age to within ±5 years of known age in three of 10 cases (30%), but conventional methods proved to be better in estimating age to within ±10 years as compared with the digital method [Table 2]. The conventional method could estimate age to within ±10 years of known age in three of 10 cases (30%) as against two of 10 cases (20%) for the digital method. But, as we moved further down, the digital method proved to be better in estimating age to within ±20 years. [Figure 4] and [Figure 5] depict scatter plots showing the correlation of translucency length to known age for the conventional and digital methods. There was no appreciable difference between the scatter plots of the two methods.
Figure 4: Scatter plot showing correlation of translucency length to age and regression line for the conventional method

Click here to view
Figure 5: Scatter plot showing correlation of translucency length to age and regression line for the digital method

Click here to view
Table 2: Accuracy of age estimation of conventional and digital methods on a control sample

Click here to view



   Discussion Top


Tomes was the first investigator to describe translucent dentine. He wrote that translucency is the result of the consolidation of the dentinal tubules and he noticed that if the air in the dentinal tubules of a tooth is replaced by water, the tooth becomes more translucent. He and Czermak held the opinion that various types of translucency arose because of an equalization of the normally different indices of refraction of the tubules and of the calcified dentine matrix. [3],[13] The alteration is believed to be due to the decreased diameter of dentinal tubules caused by increased intratubular calcification. Hence, the difference in refractive indices between intratubular organic and extratubular inorganic material is equalized, resulting in increased translucency of the affected dentin. [2]

Bang and Ramm [8] were the first to use dentin translucency alone for estimating age and reported significant increase in root translucency with age. Miles stated that among the parameters used for assessing age for forensic purposes, translucency of the root apex seems to be the most reliable or the one with the closest straight-line relationship with age. He suggested that there is a gradual extension of the processes responsible for this translucency further and further in the direction of the crown as age advances, until, in due course, the whole of the root may be affected. The same opinion was held by Johnson. [3],[14],[15],[16]

Advantages of dentin translucency as a parameter to assess age

There are compelling reasons for using dentin translucency for age assessment as compared with other variables proposed by Gustafson. It is one of the simplest to assess among Gustafson's six variables. [4] According to Miles [17] and Bang and Ramm, [8] a relatively inexperienced examiner can use it to estimate age. This parameter is least affected by environmental factors and the pathological process. [6],[18],[19],[20] It also shows symmetrical distribution on both sides of the jaws. [18],[21] Furthermore, translucency can be assessed macroscopically on intact teeth, although tooth sections provide better detail. [4],[8] For this particular reason, sectioned teeth were used in the present study. Moreover, scanning unsectioned teeth would not have facilitated translucency observation or measurement.

Comparison of conventional and digital methods

For obtaining translucency measurements, the digital method has distinct advantages over the conventional method as it has the provision of verifying the measurements made on life-size images by magnification using the zoom tool within photoshop (desired magnifications can also be selected on the navigator palette by choosing window > navigator). The magnification allows better visualization of the junction between translucent and nontranslucent zones, giving scope for "fine-tuning" the measurements. [4] A magnifier can also be used in the conventional method; however, irrespective of magnification, an impediment to caliper-based measurements is that the caliper beaks cannot always be stabilized on thin tooth sections as there is risk of damage to the thin sections from the pointed beaks. Therefore, calipers are probably better suited for measuring translucency on intact teeth. On the other hand, the "touch-free" or "noninvasive" digital evaluation prevents potential damage to thin tooth sections. [4] Furthermore, the scanned images can be easily stored and conveniently retrieved for future use, irrespective of the condition of the actual tooth section.

Applicability of digital translucency measurement in age estimation

Pearson's correlation coefficients exhibited minimal variation between the two methods [Table 1]. However, conventional measurements were better correlated to age, which is similar to the results obtained by Drusini et al.[10] and Valenzuela et al.,[22] but is in contrast to the results obtained by Acharya. [4] In the present report, age calculation using linear regression equations on the control sample (n = 10) showed similar ability for the conventional and digital methods to assess age - age was estimated to within ±5 years in 30% of the cases with both the methods. This is in contrast to a similar study conducted by Acharya, [4] in which he observed that the digital method proved to be better in estimating age - age was estimated to within ±5 years in 60% of the cases, as against 40% for the conventional method.


   Conclusion Top


A relatively simple method for measuring dentin translucency has been described using commercially available digital aids. However, the values of the dentin translucency obtained by the two methods, i.e., conventional and digital, were very similar, with no clear superiority of one method over the other. Hence, further studies on a large scale are warranted to determine which method is more reliable to estimate the age.

 
   References Top

1.Willems G. A review of the most commonly used dental age estimation techniques. J Forensic Odontostomatol 2001;19:9-17.  Back to cited text no. 1
[PUBMED]    
2.Acharya AB, Sivapathasundharam B. Forensic Odontology. In: Rajendran R, Sivapathasundharam B, editors. Shafer's Textbook of Oral Pathology. 6 th ed. Noida, India: Elsevier; 2009. p. 871-99.  Back to cited text no. 2
    
3.Vasiliadis L, Stavrianos C, Dagkalis P, Parisi KS, Stavrianou I, Tatsis D. Translucent root dentine in relationship to increasing age: Review of the literature. Res J Biol Sci 2011;6:92-5.  Back to cited text no. 3
    
4.Acharya AB. A new digital approach for measuring dentin translucency in forensic age estimation. Am J Forensic Med Pathol 2010;31:133-7.  Back to cited text no. 4
[PUBMED]    
5.Harris FE, Mincer HH, Anderson MK, Senn RD. Age estimation from oral and dental structures. In: Senn RD, Stimson GP, editors. Forensic dentistry. New York: CRC Press, Taylor and Francis Group, LLC; 2010. p. 285.  Back to cited text no. 5
    
6.Gustafson G. Age determination on teeth. J Am Dent Assoc 1950;41:45-54.  Back to cited text no. 6
[PUBMED]    
7.Johanson G. Age determination from teeth. Odontologisk Revy 1971;22:90.  Back to cited text no. 7
    
8.Bang G, Ramm E. Determination of age in humans from root dentine transparency. Acta Odontol Scand 1970;28:3-35.  Back to cited text no. 8
[PUBMED]    
9.Lamendin H, Baccino E, Humbert JF, Tavernier JC, Nossintchouk RM, Zerilli A. A simple technique for age estimation in adult corpses: The two criteria dental method. J Forensic Sci 1992;37:1373-9.  Back to cited text no. 9
    
10.Drusini A, Calliari I, Volpe A. Root dentine transparency: Age determination of human teeth using computerized densitometric analysis. Am J Phys Anthropol 1991;85:25-30.  Back to cited text no. 10
[PUBMED]    
11.Mandojana JM, Martin-de las Heras S, Valenzuela A, Valenzuela M, Luna JD. Differences in morphological age-related dental changes depending on postmortem interval. J Forensic Sci 2001;46:889-92.  Back to cited text no. 11
[PUBMED]    
12.Johansen RJ, Bowers CM. Digital analysis of bite mark evidence using adobe photoshop. Santa Barbara, CA: Forensic Imaging Services; 2000.  Back to cited text no. 12
    
13.Vasiliadis L. Root dentine translucency. Ph.D. Thesis, Bristol University, UK, 1981.  Back to cited text no. 13
    
14.Miles AE. Sans teeth: Changes in oral tissues with advancing age. Proc R Soc Med 1972;65:801-6.  Back to cited text no. 14
[PUBMED]    
15.Miles AE. Age changes in dental tissues. In: Cohen B, Kramer IR, editors. Scientific foundations of dentistry. Vol. 29. London: William Heinemann Medical Books Ltd.; 1976. p. 363-75.  Back to cited text no. 15
    
16.Johnson CC. Transparent dentine in age estimation. Oral Surg 1968;25:834-8.  Back to cited text no. 16
[PUBMED]    
17.Miles AE. Dentition in the estimation of age. J Dent Res 1963;42:255-63.  Back to cited text no. 17
    
18.Singhal A, Ramesh V, Balamurali PD. A Comparative analysis of root dentin translucency with known age. J Foernsic Dent Sci 2010;2:18-21.  Back to cited text no. 18
    
19.Nalabandian J, Gonzales F, Sognnaes RF. Sclerotic age changes in root dentin of human teeth as observed by optical, electron and X-ray microscopy. J Dent Res 1960;39:598-607.  Back to cited text no. 19
    
20.Azaz B, Michaeli Y, Nitzan D. Aging tissues of the roots of nonfunctional human teeth (Impacted Canines). Oral Surg Oral Med Oral Pathol 1977;43:572-8.  Back to cited text no. 20
[PUBMED]    
21.Solheim T. Dental root translucency as an indicator of age. Scand J Dent Res 1989;97:189-97.  Back to cited text no. 21
[PUBMED]    
22.Valenzuela A, Martin-De Las Heras S, Mandojana JM, De Dios Luna J, Valenzuela M, Villanueva E. Multiple regression models for age estimation by assessment of morphologic dental changes according to teeth source. Am J Forensic Med Pathol 2002;23:386-9.  Back to cited text no. 22
[PUBMED]    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]
 
 
    Tables

  [Table 1], [Table 2]


This article has been cited by
1 Technical note: The two step procedure (TSP) for the determination of age at death of adult human remains in forensic cases
Eric Baccino,Laura Sinfield,Sophie Colomb,Thierry Pascal Baum,Laurent Martrille
Forensic Science International. 2014; 244: 247
[Pubmed] | [DOI]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed2620    
    Printed92    
    Emailed0    
    PDF Downloaded569    
    Comments [Add]    
    Cited by others 1    

Recommend this journal